Mega-Temp™ Insulation Technical Data
| Parameter | Details |
|---|
| Density Dried | Less than 10 grams per square foot (60 kilograms per cubic meter) |
| Average Thickness | Less than 1 millimeter |
| Incombustible | Per FAR 23.853(a); FAR 25.853(b) Appendix F |
| Service Temperature | Steady State Temperature: 260 C (500 F) Transient Temperature: 1093 C (2000 F) |
| Heat Release | Passed SINTEF NBL Nordtest method NT Fire 004 NS-INSTA 412 for In 1 classification |
| Smoke Development | Does not exceed 10% density per Nordtest method NT Fire 004 NS-INSTA 412 for In 1 classification |
| Melting Point | Exceeds 1093 C (2000 F) |
| Moisture Absorption | Less than 1% |
| Permeability | Per ASTM-96 at 0.05 perms |
| Cryogenic Exposure | Experiences no deteriorating effects at -195.58 C (-320 F) (liquid nitrogen) |
| Acoustic Transmission Loss | Up to 6 decibels |
| Acoustic Absorption | Up to 9 decibels |
| Corrosion | None: No corrosive influence as applied to various metallic alloys, woods, or glass Vapor barrier properties actually help inhibit corrosion. |
| Acid Exposure | Sulfuric, nitric, hydrochloric acid inert |
| Ozone Exposure | Inert |
| Ultra Violet Exposure | Inert |
| Impact Resistance | Drop Ball Test: Experiences no delamination or cracking |
| Vermin | Does not promote bacteria, fungi, insects, or vermin |
Thermal Conductivity Data
| Thermal Conductivity | Btu·1mm/(hr·ft2·°F) |
|---|
| 23.89 C (75 F) mean | 0.26 |
| 93.33 C (200 F) mean | 0.28 |
| 148.89 C (300 F) mean | 0.31 |
| 204.44 C (400 F) mean | 0.35 |
| 260 C (500 F) mean | 0.40 |
Application Details
Mega-Temp Insulation is applied using a Low Pressure Air System.
Cure Cycle: Dry to the touch in 15 to 40 minutes. Cured 100% in 48 hrs.
Reference Acoustic Data
| Sound Source | Decibels |
|---|
| Hearing Threshold | 0 |
| Leaf Rustling | 20 |
| Library | 40 |
| Typical Home | 50 |
| Normal Speech | 60 |
| Vacuum Cleaner | 70 |
| Dial Tone on Telephone | 80 |
| City Traffic | 85 |
| Diesel Truck Nearby | 90 |
| Motorcycle | 100 |
| Chainsaw | 110 |
| Turbofan Aircraft at Takeoff @ 50 Meters | 118 |
| Commencement of Ear Pain | 125 |
| Jet Engine @ 30 Meters | 140 |
| Twelve Gauge Shotgun | 150 |
| .38 Smith & Wesson Pistol | 153 |
| .357 Magnum Pistol | 164 |
| Permanent Structural Ear Damage | 180 |
Reference Flame Temperature (Approximate)
| Energy Source / Oxidizer | Celsius | Fahrenheit |
|---|
| Acetylene/Air | 2,630 | 4,766 |
| Acetylene/Oxygen | 3,300 | 5,972 |
| Bunsen Burner | 1,575 | 2,867 |
| Butane/Air | 1,810 | 3,290 |
| Candle Lit | 1,100 | 2,012 |
| Cigar Lit | 790 | 1,454 |
| Electric Spark | 1,300 | 2,372 |
| Hydrogen/Air | 2,205 | 4,000 |
| Match Lit | 800 | 1,472 |
| Methane/Air | 1,915 | 3,479 |
| Pine Wood/Air | 1,950 | 3,542 |
| Propane/Air | 1,970 | 3,578 |
| Weather Lightning Bolt | 30,537 | 55,000 |